100watts 2.4G RF Power Amplifier /Power Transmitter/RF Transmitter Module/RF Amplifier Module

100Watts 2.4G RF Power amplifier with RS232All the parameters of PA can be customized depend on your request, if you have any customized parameters pls contact us freelyTechnical Specifications Frequency(MHz)2400-2500Input Power≤20dBmOutput Power(W)50±1(100W )ALC Range(dB)≥25In-Band ripple(dB)≤3Gain(dB)

Featured Products

100Watts 2.4G RF Power amplifier with RS232
All the parameters of PA can be customized depend on your request, if you have any customized parameters pls contact us freely

Technical Specifications
 
Frequency(MHz)2400-2500
Input Power≤20dBm
Output Power(W)50±1(100W )
ALC Range(dB)≥25
In-Band ripple(dB)≤3
Gain(dB)50 or Customized
Gain Adjustment range(dB)>31/1dB step or Customized
Gain Adjustment Linearity(dB)≤±1
Gain Flatness(dB)±0.5(Max)
Impedance(ohm)50
VSWR≤1.4:1
Voltage(V)DC+28
Power current≤11A
RF ConnectorSMA-50K or other Customized
Monitor interfaceRS-485 or RS232 or other Customized
Monitoring communication protocolsUse Manufacturers protocol or Customized
Working Temperature-40~+65 degree
Storage Temperature-55 to +85 degree
Operating Humidity0 to 90%, relative
Surface ColorMetal color conductive oxide and other color customized
weight 1.6KG
RemarkModule with output short circuit or open circuit protection
 
  
Monitoring Function Description:
No.Monitoring functionDescription
1query PA ALARMWhen an alarm amplifier failure
2SWR ALARMAmplifier output reflection is too large, VSWR exceeds 3:1, an alarm is generated
3Over temperature alarmModule internal temperature exceeds 85 ºC, generates an alarm and turn off the amplifier until the temperature returns to below 65 ºC, re-open the amplifier
4Over  output power alarmWhen the output power exceeds the nominal full power 2dB is an alarm
5Input power detectionAccuracy of ± 1dB
6Reverse power detectionAccuracy of ± 1dB
7output power detectionDetecting the actual output power amplifier,Accuracy of ± 1dB
8Temperature detectionDetection module operating temperature, detection range: -25 ~ +90 ºC, Accuracy of ± 3 ºC
10SWRDetecting amplifier output port VSWR range of 1.2 ~ 4.0
11query and setPA attenuator Set and query Set and query the value of ATT
12PA switching query and setQuery and set the state open tube amplifier
 